Skip to content

Injection Moulding Machine Manufacturer — Andheri East, Mumbai, India

Injection Moulding Machine for Veterinary Syringes

Veterinary syringes are made on horizontal injection moulding machines, with barrel, plunger and dose mechanism in separate moulds, from PC or PP for barrels and POM for ratchet parts. Barrel length and wall set shot weight and opening stroke, while cavity count sets clamp force. The ratchet that sets each repeat dose needs the closest shrinkage control.

Vet syringes run in lower volumes than human disposables and are often reused, so the mould set and material route outweigh raw output. Pratishna Engineers supplies horizontal machines for these parts and can recommend a configuration for each tool in the set.

Manufacturing Veterinary Syringes?

Share your syringe parts, materials and yearly volume, and Pratishna Engineers will suggest machines and a quotation.

Machine Requirements for Veterinary Syringe Moulding

A veterinary syringe is an assembly of several mouldings plus metal parts, each with its own demands. Selection usually covers:

  • Dried PC for clear, autoclavable reusable barrels
  • Thicker barrel walls packed out without sink or voids
  • Long barrel cores held straight for even wall
  • Stable POM shrinkage for ratchet and dose teeth
  • Sharp graduation marks on the barrel face
  • Separate TPE gasket tool sized to the bore

Recommended Machine for Veterinary Syringes

Single barrels, plungers and dose parts are small to medium mouldings that suit the E Series (75-180 T). Long barrels in multi-cavity tools, or family moulds holding several mechanism parts, can need an H Series (120-350 T) machine, or a C Series (140-320 T) where the wider platen helps, for clamp force, mould height and stroke.

Not Sure Which Machine You Need?

Send your barrel, plunger and mechanism drawings for a machine recommendation.

Request a Machine Recommendation

Why Choose Pratishna Engineers?

  • Application-Based Machine Selection
  • In-House Engineering & Manufacturing
  • Multiple Machine Series
  • Production-Focused Solutions
  • End-to-End Technical Support
  • Industry-Specific Solutions
  • Machine Lifecycle Support

Injection Moulding Machine Buyer Resources

Download practical resources to help you select, size and specify the right machine.

  • Horizontal Injection Moulding Machine Selection Guide

    Horizontal Injection Moulding Machine Selection Guide

    A step-by-step guide covering the key inputs needed to select the right machine: product weight, projected area, number of cavities, plastic material, required clamping force, shot / injection capacity, mould dimensions, production quantity, cycle time and automation requirement.

    Download PDFPDF · 265 KB
  • How to Calculate Clamping Force for an Injection Moulding Machine

    How to Calculate Clamping Force for an Injection Moulding Machine

    A clear methodology that explains how clamping force is calculated, covering projected area, injection pressure, safety factor, number of cavities and material considerations.

    Download PDFPDF · 363 KB
  • Medical Sector Components & Machine Guide

    A guide to Medical Sector components, covering syringes, IV set parts, luer fittings, connectors, pipette tips, petri dishes, test cassettes and device housings. It explains medical-grade materials, clean moulding area needs, dimensional control, and how to match each part to a suitable machine.

    Download PDFPDF · 206 KB

FAQs / Buyer Questions

Questions animal health product makers ask about moulding syringe parts.

  • Which Injection Moulding Machine Is Used to Make Veterinary Syringes?
    Most barrel, plunger and mechanism tools fit a horizontal E Series machine. Long barrels, higher cavity counts or several parts sharing one family mould call for the C or H Series.
  • Which Material Suits Reusable Veterinary Syringe Barrels?
    PC is used for clear barrels that are washed and autoclaved, with PSU where higher heat resistance is needed. PP suits single-use barrels. PC and PSU both need thorough drying and a warm mould to limit moulded-in stress.
  • How Is the Repeat-dose Ratchet Moulded Accurately?
    The ratchet is usually POM, which shrinks noticeably and varies with mould temperature and holding time. A stable mould temperature, steady holding pressure and gating that fills the teeth evenly keep each click and dose consistent.
  • Are Needles, Springs and Adjusters Moulded In?
    Usually not. Metal needles, springs and dose adjusters are assembled after moulding. The moulded parts carry the seats, threads and snap features that hold them, so those features are checked on trial parts before the mould is approved.
  • Can Pratishna Recommend a Machine for My Veterinary Syringe?
    Yes. Share drawings or samples of the barrel, plunger and mechanism parts, materials, part weights, cavities, mould dimensions and yearly quantity, and Pratishna Engineers will recommend suitable machines.
  • Does the Machine Suit Other Syringe and Injector Parts Too?
    Yes. This machine class can also produce syringe barrels, syringe plungers, autoinjector and pen injector components and needle hubs, though hubs insert moulded over cannula may need a different machine layout.

Technical Disclaimer

Disclaimer: The information provided in this webpage is for general informational and educational purposes only. It is based on technical references and industry information available at the time of preparation and may be subject to change. It does not constitute engineering, technical, commercial or professional advice, nor does it constitute a quotation, specification, warranty or contractual commitment by Pratishna Engineers.

Actual injection moulding machine and process requirements vary according to the component design, material, mould, production volume, machine configuration and operating conditions. The information, examples, calculations and recommendations provided should be independently evaluated and verified for the specific application before making any equipment, process or production decision. Information obtained from third-party sources remains subject to the accuracy and limitations of those sources.

Limitation of Liability: Pratishna Engineers makes no representation or warranty, express or implied, regarding the completeness, accuracy or suitability of the information for any particular application. To the extent permitted by applicable law, Pratishna Engineers shall not be liable for any loss, damage, cost or consequence arising from reliance on or use of the information contained in this webpage. Final machine selection, configuration and application suitability should be confirmed with Pratishna Engineers based on complete and accurate project requirements.

Talk to Our Engineers

Planning a New Injection Moulding Project?

Share your component, material, mould and production target. Our engineering team will help you identify the right machine configuration.

Machine Sales
+91 99690 38542
Service Support
+91 97689 28259

Download the PDF