Skip to content

Injection Moulding Machine Manufacturer — Andheri East, Mumbai, India

Injection Moulding Machine for Dosing Cups and Oral Dosing Spoons

Dosing cups and oral dosing spoons are moulded on horizontal injection moulding machines, using multi-cavity hot runner tools, from medical-grade PP, PS or PE. Cavity count and cup depth set the clamp and opening stroke. Dose accuracy matters most, since the internal volume each graduation marks has to hold after shrinkage.

Machine selection for dosing cups focuses on cavity-to-cavity consistency, steady core position for even walls and a process that repeats lot after lot. Pratishna Engineers supplies horizontal injection moulding machines for dosing cups and spoons and can recommend a configuration for your part, mould and volume.

Manufacturing Dosing Cups?

Share your cup or spoon drawing, resin and cavity target, and Pratishna Engineers will recommend a machine.

Machine Requirements for Dosing Cup and Spoon Moulding

A dosing cup looks like a giveaway part, but its marked volume is a regulated claim checked by fill test:

  • Balanced hot runner filling for equal volume in every cavity
  • Core alignment that keeps cup walls even and centred
  • Mould temperature control so graduations hold after shrinkage
  • Clear PP or PS grades free of specks and splay
  • Opening stroke and ejection suited to deep nesting cups
  • Gate placed off the graduation scale and spoon bowl

Recommended Machine for Dosing Cups and Spoons

Cups and spoons are light parts run in high-cavity tools, so total projected area and mould size set the clamp. Lower-cavity cup and spoon moulds can sit on the Hybrid PH Series (120-140 T) or the E Series (75-180 T). High-cavity hot runner tools and deeper cups usually go to H Series (120-350 T) machines, or C Series (140-320 T) for a wider mould.

Not Sure Which Machine You Need?

Send the cup or spoon drawing and cavity plan for a recommendation.

Request a Machine Recommendation

Why Choose Pratishna Engineers?

  • Application-Based Machine Selection
  • In-House Engineering & Manufacturing
  • Multiple Machine Series
  • Production-Focused Solutions
  • End-to-End Technical Support
  • Industry-Specific Solutions
  • Machine Lifecycle Support

Injection Moulding Machine Buyer Resources

Download practical resources to help you select, size and specify the right machine.

  • Horizontal Injection Moulding Machine Selection Guide

    Horizontal Injection Moulding Machine Selection Guide

    A step-by-step guide covering the key inputs needed to select the right machine: product weight, projected area, number of cavities, plastic material, required clamping force, shot / injection capacity, mould dimensions, production quantity, cycle time and automation requirement.

    Download PDFPDF · 265 KB
  • How to Calculate Clamping Force for an Injection Moulding Machine

    How to Calculate Clamping Force for an Injection Moulding Machine

    A clear methodology that explains how clamping force is calculated, covering projected area, injection pressure, safety factor, number of cavities and material considerations.

    Download PDFPDF · 363 KB
  • Medical Sector Components & Machine Guide

    A guide to Medical Sector components, covering syringes, IV set parts, luer fittings, connectors, pipette tips, petri dishes, test cassettes and device housings. It explains medical-grade materials, clean moulding area needs, dimensional control, and how to match each part to a suitable machine.

    Download PDFPDF · 206 KB

FAQs / Buyer Questions

What oral dosing accessory makers ask before ordering a machine.

  • Which Injection Moulding Machine Is Used to Make Dosing Cups and Spoons?
    A horizontal machine sized by cavity count and cup depth. Hybrid PH and E Series models suit lower-cavity tools, and high-cavity hot runner moulds for cups or spoons move to the C or H Series.
  • How Is Dose Accuracy Checked on a Measuring Cup?
    By fill test on moulded parts, not by measuring the tool. Cups from each cavity are filled to the graduation and the volume is checked, and the test is repeated after any change of resin, mould or process.
  • Which Resin Is Used for Dosing Cups and Spoons?
    Medical-grade PP is common for cups and spoons, with clarity grades so the patient can read the liquid level. PS gives a rigid clear cup, and PE suits softer spoons. Grades are chosen for contact with the medicine.
  • Why Is a Medical Dosing Cup Different From a Kitchen Measuring Cup?
    The moulding is similar, but the medical version carries a dose claim. That brings lot traceability, validated graduations and fill testing, so the machine has to hold the same process across long runs and resin lots.
  • Can Pratishna Recommend a Machine for My Dosing Cup or Spoon?
    Yes. Share the cup or spoon drawing, resin, part weight, cavity count, mould dimensions and annual quantity, and Pratishna Engineers will recommend a suitable machine.
  • Does the Machine Suit Other Pharma Consumables Too?
    Yes, subject to the mould. Medication trays, droppers, pharma vial closures and specimen containers can run on the same class of machine, each with its own tool.

Technical Disclaimer

Disclaimer: The information provided in this webpage is for general informational and educational purposes only. It is based on technical references and industry information available at the time of preparation and may be subject to change. It does not constitute engineering, technical, commercial or professional advice, nor does it constitute a quotation, specification, warranty or contractual commitment by Pratishna Engineers.

Actual injection moulding machine and process requirements vary according to the component design, material, mould, production volume, machine configuration and operating conditions. The information, examples, calculations and recommendations provided should be independently evaluated and verified for the specific application before making any equipment, process or production decision. Information obtained from third-party sources remains subject to the accuracy and limitations of those sources.

Limitation of Liability: Pratishna Engineers makes no representation or warranty, express or implied, regarding the completeness, accuracy or suitability of the information for any particular application. To the extent permitted by applicable law, Pratishna Engineers shall not be liable for any loss, damage, cost or consequence arising from reliance on or use of the information contained in this webpage. Final machine selection, configuration and application suitability should be confirmed with Pratishna Engineers based on complete and accurate project requirements.

Talk to Our Engineers

Planning a New Injection Moulding Project?

Share your component, material, mould and production target. Our engineering team will help you identify the right machine configuration.

Machine Sales
+91 99690 38542
Service Support
+91 97689 28259

Download the PDF

Share your details and the download starts straight away.